DualPDA

Image of DualPDA receiver

The DualPDA receiving probe contains four receiving apertures integrated into one single optical unit.  This novel concept yields a higher measurement accuracy, particularly for spray analysis and other investigations of liquid atomisation.

The DualPDA detector configuration (2 standard and 2 planar), combined with sophisticated validation routines, is not susceptible to unwanted effects resulting from the Gaussian light intensity distribution in the measurement volume. Misinterpreted size measurements due to trajectory effects are therefore eliminated.

The DualPDA provides the same flexibility in configuration as the FiberPDA.

Components

BSA Flow Software

BSA Flow Software

Combined with Dantec’s LDA processors and optical LDA systems, BSA Flow Software provides an integrated, flexible, and easy-to-use solution for all LDA fluids experiments
LEARN MORE

BSA Flow Particle Sizing add-on

BSA Flow Particle Sizing add-on

The Particle Sizing Add-on for the BSA Flow Software enables easy set-up of PDA systems and advanced data analysis.
LEARN MORE

Burst Spectrum Analyzer

Burst Spectrum Analyzer

Fast and powerful all-in-one processor for LDA & PDA systems
LEARN MORE

Intensity Validation

Intensity Validation

Intensity validation compares the signal intensity from each particle with measured size, and reject erroneous results outside of acceptance bounds
LEARN MORE

Probe Supports and benches

Probe Supports and benches

Rigid benches and highly robust and stable probe supports with fine adjustments to ensure good overlap of the probe volumes in 3D LDA as well as PDA applications
LEARN MORE

PCs and Workstations

PCs and Workstations

PC or Workstation to control your measurement system; store, analyze and post-process the data; and visualize the results
LEARN MORE

Traverse Systems

Traverse Systems

Map fluid velocity in space and perform boundary layer measurements with this high resolution system
LEARN MORE

Laser safety

Laser safety

Laser protective eyewear – Eye protection against hazardous laser light is essential for your safety.
LEARN MORE

FiberPDA/Dual PDA receiver

FiberPDA/Dual PDA receiver

Compact fiber-based PDA receiver probe for simultaneous particle size and velocity measurements
LEARN MORE

HiDense PDA receiver

HiDense PDA receiver

HiDense – the Fiber-based PDA receiver probe optimized for ultra-high particles density measurements
LEARN MORE

Download Library

TITLE
DOWNLOAD FILE
DOWNLOAD FILE
PDF
DOWNLOAD FILE
FILE

Learn more about the DualPDA system today

Our global network of friendly and knowledgeable distributors is standing by to discuss your testing needs.